Probable Cause:
- Drive’s internal boost circuit is reporting >400V DC on the bus.
Corrective Action:
- Verify line voltage isn’t spiking.
- Check the internal AC wiring of the treadmill.
- Verify correct voltage controller is used with regard to power at the outlet.
- Replace the Drive Controller if the error continues.