Do you have a BowFlex M3 Max Trainer and it doesn't power up? Your console won't come on?
A good, working, console of the Max Trainer M3 by BowFlex will power up under 1 of the following conditions:
- If it is plugged into a power source.
- If any button is pushed.
- If it receives a signal from the RPM sensor as a result of pedaling the machine.
Sportsmith offers some things you can check if your Bowflex Max Trainer M3 console does not power up.
What to Check if your Console Doesn't Power Up:
- Make sure the unit is using a working outlet. Test the outlet with a lamp or fan.
- Check the power cord for any damage.
- Check the connections at the front of the unit.
- The connection should be secure and undamaged. If damage is present, replace the adapter or the connection at the unit.
- Check the data cable connections and alignment.
- The data cable should be secure and in proper alignment. The small latch on the connector should line up and snap into place.
- Check the data cable integrity.
- All wires in the cable should be intact. If any cuts or crimping, replace the cable.
- Check cable for continuity. Click here for help with continuity. Replace the cable if continuity is lacking.
- Reset the machine.
- Unplug the unit from the electrical outlet for 5 minutes, then reconnect it.
- Check magnet and speed sensor. Shrouds must be removed.
- Magnet should be in place on the fan disc.
- Sensor should be aligned with magnet. Adjust gap if necessary.
- Using magnet and multi-meter, check function of the speed sensor.
- The continuity should poll between opened and closed as the magnet is moved close and then taken away from the sensor. If continuity stays opened or closed no matter the presence of the magnet the sensor is faulty.
- Note: Place probes on speed sensor connector and hold magnet along side of the sensor. Do Not place magnet at end of sensor; this can give false readings.
- Replace the speed sensor if faulty.
Parts mentioned above that may need replacing:
- Data Cable - OEM# 8003603
- Power Adapter - OEM# 8007982
- Power Plug Connector (connection at unit) - OEM# 8003600
- Speed Sensor - OEM# 8004557
Tech Tip
- Try pressing the power button several times.
- If you have a spare power cord, try using that one.
- If you have a spare data cable, try using that one.
If you have tried all the above and the console still does not power up, replace the console. Console is OEM# 8004544.