Waxer Disconnect Error on LifeFitness 9100 Treadmill

Probable Cause

  1. Disconnected or faulty wax power cord.
  2. The circuit breaker (3 amp) has tripped or is faulty.
  3. The CPU control board is faulty.

Corrective Action

  1. Inspect the waxer cable for damage and ensure it is connected to the electrical outlet on the treadmill front frame assembly.
  2. Inspect the 3 amp circuit breaker. Test and replace circuit breaker if necessary.
  3. Test unit with a known good CPU control board. Replace CPU control board if necessary.