Waxer No AC Power Error on LifeFitness 9700, 9100 and 9500 Next Gen Treadmills

Probable Cause

  1. Broken, damaged, or unplugged harness or Defective Wax/Lift PCB.
  2. Faulty wax motor or wire harness.

Corrective Action

  1. Inspect wire harness for wax/lift PCB.
    1. Reset or replace the waxer harness as necessary.
  2. Cycle motor in waxer manual mode in diagnostics and verify 120VAC at the P6 connector on the Wax/Lift PCB.     
    1. If voltage exists, verify that the cable from the Wax/Lift PCB to the waxer motor has continuity.      
      1. If continuity exists, replace the wax motor. 
      2. If no continuity, replace the wire harness.     
    2. If no voltage exists, replace the Wax/Lift PCB.