Probable Cause
Controller PCBA NVRAM Failure
Corrective Action
Re-initialize NVRAM:
- Press Stop, Faster, and Slower to enter service mode.
- Press Stop and Cool Down to reinitialize (For HR Club Track Plus, press the NC PROGRAM LOAD TEST key and proceed to step 4)
- Press Clear
- Reconfigure controller (HR Plus, adjust the contrast after reconfiguring) If error E105 persists, replace the controller.