95Xi LifeFitness Crosstrainer Video, Pedal Lever Replacement

Video demonstrates the procedure of replacing the pedal lever assembly on a 95Xi LifeFitness crosstrainer.

Tools Required:

  • 2MM Allen Wrench
  • 5/32” Allen Wrench
  • Phillips Screwdriver
  • T50 Torx Driver
  • T25 Torx Driver

Procedure:

  1. Remove all (4) screws from the main shroud
    1. There are (2) screws on each side
  2. Lift straight up to remove the main shroud
  3. Remove the (6) screws securing the outer link cover to the inner link cover
    1. There are (3) screws at the top and (3) screws at the bottom
  4. Remove the outer lever joint and rocker arm covers as seen in the replacement procedure of the outer joint and rocker covers
  5. Remove the Torx screws securing the pedal rocker shaft to the pedal lever
  6. Then slide the pedal rocker shaft out of both the pedal lever and the rocker arm
  7. Remove the bolt securing the crank extension to the crank arm
  8. Remove the set screws securing the shaft collar to the crank arm using the 2MM Allen wrench
  9. Remove the pedal lever assembly
  10. Install the new pedal lever assembly in reverse order
  11. This completes our demonstration of the replacement procedure for pedal lever assembly on a 95Xi LifeFitness crosstrainer