Jody Lay
Articles
-
Sportsmith's Wipe Dispenser
This article and video are to help demonstrate our wipe dispenser. This wide dispenser is 10 1/2" wide by 12 3/4" tall by 9 5/16" deep. The usable space inside has a diameter of 8 5/8" and i...
-
Life Fitness 95R Elevation Series Recumbent Bike Seat Cable Replacement
This article will help you replace the seat cable and handle for the seat position adjustment on Life Fitness Elevation Series Recumbent bikes. Tools Required: Phillips Screwdriver 3/16" Hex k...
-
High Voltage (220volt) Life Fitness Treadmills CLL100004-CLL161748 Motor Control Board Replacement
This document applies to 220volt units with serial numbers: CLL100004-CLL161748. These units can use motor control board ak75-00005-0001, Sportsmith item P01AK7500050001 with some setup and require...
-
How to Replace Bowflex Max Trainer Servo Motor
This article details how to replace the servo motor on the Bowflex Max Trainer models M5, M6, M7, M8, M9, and M9i. Before servo motor replacement, inspect the cable that connects the flywheel to th...
-
How to Reset a Bowflex MaxTrainer M5 Console
The following steps to reset the console of a Bowflex M5 Max Trainer apply to the model SKUs 100702 and 100359. These steps apply to the serial numbers beginning 8003601. Note: Resetting the consol...
-
Treadmill Lift Motor Replacement using Precor C956i Treadmill
This video shows how to replace the elevation motor on a treadmill. Though we use a Precor C956i for this video, the lift motor replacement process is similar on many makes and models. Turn off...
-
Broken Wedge Pins On Your Schwinn Airdyne?
Some Schwinn Airdyne exercise bikes use a wedge pin for the crank arms. Over time and with wear, the wedge pin will become loose and needs to be tightened. The wedge pin must be tightened more ofte...
-
How To Reset Your Sportsmith Website Password
Check out our 30-second video about how to reset your Sportsmith website password! We launched a new site in June of 2022 and Sportsmith account holders were required to do this once for securit...
-
Stairmaster 4000PT Stepper Alternator Belt Replacement Procedure
This procedure covers the steps required to replace the alternator belt on a Stairmaster 4000PT. Tools Required: 19mm Wrench 13mm Wrench Or an adjustable wrench Procedure Note: We begin with the...
-
Keiser M3 Indoor Cycle Calibration without Calibration Tool
Follow these steps to calibrate a Keiser M3 Indoor Cycle computer without the use of a calibration tool. To begin, start with the shifter in the down position Plug the circuit board wire into the ...